Auxiliary heating
To provide maximum passenger convenience and ideal engine pre-heating, it is essential that heaters always start reliably. The combustion quality must remain constant over the gear pump's service life, and the suction performance must be sufficient even in critical installation situations. We can provide all of this with our decades of experience in the field of burner gear pumps.
Operating ranges
| Flow rate | 1 l/h to 40 l/h |
| Differential pressure | 7 bar to 15 bar |
| Viscosity range | 0.7 mPas to 20 mPas |
| Suction head | Up to 8 m |
| Temperature range | -40°C to 80°C |
| Inlet pressure | -0.8 to 1 bar |
| Pressure controller | Adjustable between 5 and 15 bar, +- 0.2 bar |
| Solenoid valve | 12V or 24V |
Examples of fluids
- Gasoline
- Diesel
- Biodiesel
- Kerosene
- Heating oil
Examples of applications
- Auxiliary heating in buses
- Auxiliary heating in trucks
- Auxiliary heating in streetcars